Produktai skirti dakor dyf42sbiwr (58)

FLRY-B FB250

FLRY-B FB250

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB250 CROSS SECTION (Cu):2,50 mm² STRANDED COPPER CONDUCTER (Cu):50x0,24 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 2,85 MIN. WALL THICKNESS (mm):0,28 APPROXIMATE WEIGHT (kg/km):26,00 CONDUCTOR RESISTANCE:<7,6 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
H05V-K/H07V-K (NYAF) FCVK2500

H05V-K/H07V-K (NYAF) FCVK2500

Areas of Usage: This cable type is used in automation panel installation and internal installations of electrical devices. PRODUCT CODE:FCVK2500 CROSS SECTION (Cu):25,00 mm² (H07V-K) STRANDED COPPER CONDUCTER (Cu):196x0,39mm INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC 9,40 APPROXIMATE WEIGHT (kg/km):262 CONDUCTOR RESISTANCE:<0,780Ω/km WORKING TEMPERATURE:-40 to +70°C
H05V-K/H07V-K (NYAF) FCVK150

H05V-K/H07V-K (NYAF) FCVK150

Areas of Usage: This cable type is used in automation panel installation and internal installations of electrical devices. PRODUCT CODE:FCVK150 CROSS SECTION (Cu):1,50 mm² (H07V-K) STRANDED COPPER CONDUCTER (Cu):27x0,25 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC 2,85 APPROXIMATE WEIGHT (kg/km):19 CONDUCTOR RESISTANCE:<13,3 Ω/km WORKING TEMPERATURE:-40 to +70°C
FLRY-B FB1000

FLRY-B FB1000

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB1000 CROSS SECTION (Cu):10,00 mm² STRANDED COPPER CONDUCTER (Cu):80x0,39mm INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B AND CLASS C) 5,75 MIN. WALL THICKNESS (mm):0,48 APPROXIMATE WEIGHT (kg/km):108,00 CONDUCTOR RESISTANCE:<1,82 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B FB300

FLRY-B FB300

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB300 CROSS SECTION (Cu):3,00 mm² STRANDED COPPER CONDUCTER (Cu):44x0,29 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 3,25 MIN. WALL THICKNESS (mm):0,32 APPROXIMATE WEIGHT (kg/km):34,00 CONDUCTOR RESISTANCE:<6,15 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
H05V-K/H07V-K (NYAF) FCVK3500

H05V-K/H07V-K (NYAF) FCVK3500

Areas of Usage: This cable type is used in automation panel installation and internal installations of electrical devices. PRODUCT CODE:FCVK3500 CROSS SECTION (Cu):35,00 mm² (H07V-K) STRANDED COPPER CONDUCTER (Cu):276x0,39mm INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC 11,2 APPROXIMATE WEIGHT (kg/km):350 CONDUCTOR RESISTANCE:<0,554 Ω/km WORKING TEMPERATURE:-40 to +70°C
FLRY-B FB200

FLRY-B FB200

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB200 CROSS SECTION (Cu):2,00 mm² STRANDED COPPER CONDUCTER (Cu):28x0,29 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 2,65 MIN. WALL THICKNESS (mm):0,28 APPROXIMATE WEIGHT (kg/km):23,00 CONDUCTOR RESISTANCE:<9,42 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-A FA150

FLRY-A FA150

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FA150 CROSS SECTION (Cu):1,50 mm² STRANDED COPPER CONDUCTER (Cu):19x0,32 mm INSULATION MATERIAL AND DIAMETER(mm ±0,03):PVC (according to ISO 6722-1, CLASS B and CLASS C) 2,4 WALL THICKNESS min (mm):0,20 APPROXIMATE WEIGHT (kg/km):16,00 CONDUCTOR RESISTANCE:<12,7 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B FB600

FLRY-B FB600

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB600 CROSS SECTION (Cu):6,00 mm² STRANDED COPPER CONDUCTER (Cu):84x0,29 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 4,15 MIN. WALL THICKNESS (mm):0,32 APPROXIMATE WEIGHT (kg/km):61,00 CONDUCTOR RESISTANCE:<3,14 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
H05V-K/H07V-K (NYAF) FCVK5000

H05V-K/H07V-K (NYAF) FCVK5000

Areas of Usage: This cable type is used in automation panel installation and internal installations of electrical devices. PRODUCT CODE:FCVK5000 CROSS SECTION (Cu):50,00 mm² (H07V-K) STRANDED COPPER CONDUCTER (Cu):396x0,39mm INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC 13,00 APPROXIMATE WEIGHT (kg/km):510 CONDUCTOR RESISTANCE:<0,386 Ω/km WORKING TEMPERATURE:-40 to +70°C
FLRY-B FB400

FLRY-B FB400

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB400 CROSS SECTION (Cu):4,00 mm² STRANDED COPPER CONDUCTER (Cu):56x0,29 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 3,55 MIN. WALL THICKNESS (mm):0,32 APPROXIMATE WEIGHT (kg/km):42,00 CONDUCTOR RESISTANCE:<4,71 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-A FA250

FLRY-A FA250

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FA250 CROSS SECTION (Cu):2,50 mm² STRANDED COPPER CONDUCTER (Cu):19x0,41, mm INSULATION MATERIAL AND DIAMETER(mm ±0,03):PVC (according to ISO 6722-1, CLASS B and CLASS C) 3,0 WALL THICKNESS min (mm):0,28 APPROXIMATE WEIGHT (kg/km):26,00 CONDUCTOR RESISTANCE:<7,6 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B FB3500

FLRY-B FB3500

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB3500 CROSS SECTION (Cu):35,00 mm² STRANDED COPPER CONDUCTER (Cu):276x0,39mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 9,90 MIN. WALL THICKNESS (mm):0,56 APPROXIMATE WEIGHT (kg/km):371,00 CONDUCTOR RESISTANCE:<0,527 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B FB150

FLRY-B FB150

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB150 CROSS SECTION (Cu):1,50 mm² STRANDED COPPER CONDUCTER (Cu):30x0,24 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 2,30 MIN. WALL THICKNESS (mm):0,24 APPROXIMATE WEIGHT (kg/km):16,00 CONDUCTOR RESISTANCE:<12,7 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
H05V-K/H07V-K (NYAF) FCVK1600

H05V-K/H07V-K (NYAF) FCVK1600

Areas of Usage: This cable type is used in automation panel installation and internal installations of electrical devices. PRODUCT CODE:FCVK1600 CROSS SECTION (Cu):16,00 mm²(H07V-K) STRANDED COPPER CONDUCTER (Cu):126x0,39mm INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC 6,75 APPROXIMATE WEIGHT (kg/km):167 CONDUCTOR RESISTANCE:<1,21 Ω/km WORKING TEMPERATURE:-40 to +70°C
H05V-K/H07V-K (NYAF) FCVK400

H05V-K/H07V-K (NYAF) FCVK400

Areas of Usage: This cable type is used in automation panel installation and internal installations of electrical devices. PRODUCT CODE:FCVK400 CROSS SECTION (Cu):4,00 mm² (H07V-K) STRANDED COPPER CONDUCTER (Cu):56x0,29 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC 3,95 APPROXIMATE WEIGHT (kg/km):44 CONDUCTOR RESISTANCE:<4,95Ω/km WORKING TEMPERATURE:-40 to +70°C
FLRY-B FB1600

FLRY-B FB1600

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB1600 CROSS SECTION (Cu):16,00 mm² STRANDED COPPER CONDUCTER (Cu):126x0,39mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 6,80 MIN. WALL THICKNESS (mm):0,52 APPROXIMATE WEIGHT (kg/km):170,00 CONDUCTOR RESISTANCE:<1,16 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
DYNACO M2/M3 ALL WEATHER - Lauke

DYNACO M2/M3 ALL WEATHER - Lauke

Install Dynaco M2/M3 ALL WEATHER high-speed roll-up doors if your building is often exposed to strong winds. Thanks to a superior and tight seal this medium sized high-speed door is wind resistant up to class 5 (M2) or class 4 (M3) of the European standard EN 12424. The fast door cycle combined with push-pull drive technology ensures uninterrupted continuation of your production, transport or logistic activities, even in bad weather conditions. Maximum height:H 5.500 mm Maximum width:W 5.500 mm (M2) - 8.000 mm (M3) Opening speed:up to 2,4 m/s (M2) - 1,4 m/s (M3) Closing speed:1,2 m/s (M2) - 0,6 m/s (M3)
DYNACO D-641 POWER - Išorė

DYNACO D-641 POWER - Išorė

The Dynaco D-641 Power high-speed door is a perfect high-speed door for outside use. It is wind resistant up to class 4 according to the European standard EN 12424. Its superior tight seal and fast door cycle allow for significant energy savings. Wind and bad weather are excluded from your building, keeping your infrastructure and goods well protected. Maximum height:H 5.500 mm Maximum width:W 5.500 mm Opening speed:up to 3,6 m/s Closing speed:up to 1,2 m/s
DYNACO D-651 ALL WEATHER - Lauke

DYNACO D-651 ALL WEATHER - Lauke

Thanks to the superior and tight seal around the full perimeter of the roll up door, the Dynaco D-651 All Weather high-speed door is wind resistant up to class 5 of the European standard EN 12424. This exterior high speed roll up door protects your premises against wind, bad weather and extreme temperatures. It ensures energy savings and optimized traffic flows, logistic and transport activities. Maximum height:H 5.500 mm Maximum width:W 5.500 mm Opening speed:up to 3,6 m/s Closing speed:up to 1,2 m/s
DYNACO D-631 COMPACT

DYNACO D-631 COMPACT

The medium sized Dynaco D6 Compact is an ideal interior high-speed door suited for industrial and logistic activities. Its fast operating speed enables smooth traffic of goods, materials and personnel. Powered by advanced push-pull technology, this fast roll-up door needs little maintenance and is designed for a long lifetime. Down-time is minimized thanks to the self-reinserting flexible door curtain and one person maintainability. Maximum height:H 5.500 mm Maximum width:W 5.500 mm Opening speed:up to 3,6 m /s Closing speed:1,2 m/s
Samsung A50 - Samsung

Samsung A50 - Samsung

Samsung A50 - Samsung Référence:V-SA50-128-B-AB En stock:0 Produits Grade:Grade AB Stockage:128 Go Couleur:Noir
NEODUR PFM-ZE Flex - PFM-ZE Flex

NEODUR PFM-ZE Flex - PFM-ZE Flex

Werksmäßig hergestellter, zementgebundener Pflasterfugenmörtel mit Natursandbasis (0-2 mm), und Zusätzen zur Verbesserung der Mörteleigenschaften zur Verfugung von Plattenflächen in starrer Bauweise (Bauklasse IV bis VI). Eigenschaften:sehr guter Fließ- u. Verdichtungsgrad hohe Druck-, Biege- u .Haftzugfestigkeit Lieferform:25 kg Papierspezialverpackung
Taylor 512ce-N LH

Taylor 512ce-N LH

Größe: 4/4, Decke: Zeder (Cedar), Boden/Zargen: Mahagoni, Konstruktion: vollmassiv, Cutaway: Ja, Farbe: Natur, Finish: Hochglanz, Griffbrett: Ebenholz, Mensur: 65 cm, Sattelbreite: 47,6 mm,...
Tc 525 2i

Tc 525 2i

Tissu 100% COTON chaine & tram e Retors, arm ure reps 2/1, 530g/m2, 123 & 155cm, traite 2i (imperimpu) Principales utilisations:sacs, pochettes, cabas, bagagerie, baches, entoilages de tentes
Metalinė įrankių dėžė 502-automatinis modelis - Įrankių dėžė

Metalinė įrankių dėžė 502-automatinis modelis - Įrankių dėžė

Metal Toolbox 502-Automatic Model - Tool Box
FABRICO ER80SB6

FABRICO ER80SB6

Copper coated low alloy solid wire Uniform coper coating The recommended preheat and interpass temperature 350440°C The weld deposit in typical 5Cr0.5Mo Air hardenable alloy Radiographic weld quality
PCD niuansai ir pjovimo briaunų tipai

PCD niuansai ir pjovimo briaunų tipai

Pour le PCD, la gamme des différentes nuances est plus restreinte que pour le PcBN, ce qui simplifie beaucoup le choix. Les nuances se différencient principalement par leur microstructure, ainsi que par la taille de grain. MAPAL offre ici une sélection de nuances qui ont fait leurs preuves et qui sont les mieux indiquées pour des plaquettes performantes et de haute précision. Pour les matériaux à copeaux longs, comme par exemple les alliages d’aluminium à faible teneur en silice, MAPAL propose des plaquettes avec brise copeau. Deux variantes sont disponibles en standard, offrant toutes deux une structure spécialement développée pour une casse du copeau maîtrisée, pour l’usinage de finition et l’usinage à forte profondeur de coupe. Les copeaux sont comprimés et cassés sans coller à la structure de la pièce et sans formation d’arête rapportée.